  Datasheet File OCR Text:
  3line filters for converters and power electronics 530/305 v , 50/60 hz, 16 ...200 a, 50 c ordering code: b84143d0xxxr127 date: 20070329 v ersion: 03 ? epcos ag 2007. reproduction, publication and dissemination of this data sheet, enclosures hereto and the information contained therein without epcos' prior express consent is prohibited.
3line filters b84143d0xxxr127 for converters and power electronics construction  3line filter  metal case  book size features  high insertion loss  optimized for long cable  easy to install  low weight  compact design  degree of protection ip 20 1 )  design complies with en 60939, ul 1283, csa 22.2 no.8  optimized for long motor cable and operation under full load en 5501 1, class a & b applications  frequency converters for motor drives, e.g. elevators pumps traction systems conveyor systems hv ac systems (heating, ventilation and air conditioning)  power supplies  t extile machines t erminals  line side: fingersave terminal blocks  load side: fingersave terminal blocks marking  marking on component: manufacturer ' s logo, ordering code, rated voltage, rated current, rated temperature, climatic category , date code  minimum marking on packaging: manufacturer ' s logo, ordering code, date code, quantity 1 ) t o iec 60529:2001 please read important notes and cautions and warnings at the end of this document.    



3line filters b84143d0xxxr127 for converters and power electronics t ypical circuit diagram line load l1 l2 l3 pe l1' l2' l3' b84143d0016r127 b84143d0035r127: line load l1 l2 l3 pe l1' l2' l3' b84143d0050r127 b84143d0200r127: please read important notes and cautions and warnings at the end of this document.    



3line filters b84143d0xxxr127 for converters and power electronics t echnical data and measuring conditions rated voltage u r 530/305 v ac rated frequency f r 50/60 hz t est voltage line to line for 2 s u t e s t 2200 v dc t est voltage line to case for 2 s u t e s t 2700 v dc rated temperature t r 50 c overload capability (thermal) for 3 min per hour or for 30 s per hour 1.5 x i r 2.5 x i r climatic category (iec 600681) 25/100/21 t ypical motor cable length to comply with din en 5501 1 (2003) ordering code i r emc limits according to din en 5501 1 (2003) 1 ) a class a class b b84143d0016r127 16 300m 100m b84143d0025r127 25 300m 100m b84143d0035r127 35 300m 100m b84143d0050r127 50 300m 200m B84143D0075R127 75 300m 200m b84143d0090r127 90 300m 200m b84143d0120r127 120 300m 200m b84143d0150r127 150 300m 200m b84143d0200r127 200 300m 200m 1): t ypical values. the motor cable length depends on the clock frequency and the disturbance level of the frequency converter and migth dif fer from above mentioned indicated cable lenghts. please note pages 16 and 17. please read important notes and cautions and warnings at the end of this document.    



3line filters b84143d0xxxr127 for converters and power electronics characteristics and ordering codes i r t erminal cross section i l e a k 2 ) r t y p approx. weight ordering code approvals a mm 2 ma m w kg 16 4 < 37 14,5 2,5 b84143d0016r127 x x x 25 6 < 43 7,0 2,5 b84143d0025r127 x x x 3 5 10 < 40 4,5 3,5 b84143d0035r127 x x x 50 25 < 55 2,5 5,5 b84143d0050r127 x x x 75 50 < 73 1,0 8,0 B84143D0075R127 x x x 90 50 < 166 1,0 8,0 b84143d0090r127 x x x 120 95 < 166 1,0 14,5 b84143d0120r127 x x x 150 95 < 136 0,5 17,0 b84143d0150r127 x x x 200 95 < 139 0,5 18,5 b84143d0200r127 x x x x = in preparation 2) 3 phase operation in tn network; maximum voltage = u r ; frequency = 50 hz without harmonics; tolerance of capacitors 20%/ 0%; worst case positioning of the components; unbalance 2% according en 50160:2000. please read important notes and cautions and warnings at the end of this document.    



3line filters b84143d0xxxr127 for converters and power electronics dimensional drawings b84143d0016r127 please read important notes and cautions and warnings at the end of this document.   



3line filters b84143d0xxxr127 for converters and power electronics dimensional drawings b84143d0025r127 please read important notes and cautions and warnings at the end of this document. 
 



3line filters b84143d0xxxr127 for converters and power electronics dimensional drawings b84143d0035r127 please read important notes and cautions and warnings at the end of this document.   



3line filters b84143d0xxxr127 for converters and power electronics dimensional drawings b84143d0050r127 please read important notes and cautions and warnings at the end of this document.   



3line filters b84143d0xxxr127 for converters and power electronics dimensional drawings B84143D0075R127; b84143d0090r127 please read important notes and cautions and warnings at the end of this document.    



3line filters b84143d0xxxr127 for converters and power electronics dimensional drawings b84143d0120r127; b84143d0150r127 please read important notes and cautions and warnings at the end of this document.     



3line filters b84143d0xxxr127 for converters and power electronics dimensional drawings b84143d0200r127 please read important notes and cautions and warnings at the end of this document.    



3line filters b84143d0xxxr127 for converters and power electronics insertion loss (typical values at z = 50  ) b84143d0035r127 f  db unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) dif ferential mode (symmetrical) b84143d0050r127 f  db b84143d0025r127 f  db b84143d0016r127 f 10 4 10 5 10 6 10 7 hz  db 0 20 40 60 80 120 100 10 4 10 5 10 6 10 7 hz 0 20 40 60 80 120 100 10 4 10 5 10 6 10 7 hz 0 20 40 60 80 120 100 10 4 10 5 10 6 10 7 hz 0 20 40 60 80 120 100 please read important notes and cautions and warnings at the end of this document.    



3line filters b84143d0xxxr127 for converters and power electronics insertion loss (typical values at z = 50  ) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) dif ferential mode (symmetrical) b84143d0120r127 f  db b84143d0150r127 f  db b84143d0090r127 f  db B84143D0075R127 f  db 10 4 10 5 10 6 10 7 hz 0 20 40 60 80 120 100 10 4 10 5 10 6 10 7 hz 0 20 40 60 80 120 100 0 20 40 60 80 120 100 0 20 40 60 80 120 100 10 4 10 5 10 6 10 7 hz 10 4 10 5 10 6 10 7 hz please read important notes and cautions and warnings at the end of this document.    



3line filters b84143d0xxxr127 for converters and power electronics insertion loss (typical values at z = 50  ) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) dif ferential mode (symmetrical) b84143d0200r127 f  db 10 4 10 5 10 6 10 7 hz 0 20 40 60 80 120 100 please read important notes and cautions and warnings at the end of this document.    



3line filters b84143d0xxxr127 for converters and power electronics caution and warnings  please note the advices in our data book aemc filterso (latest edition); attention should be paid to the chapter ageneral safety noteso.  it shall be ensured that only qualified persons (electricity specialists) are engaged on work such as planning, assembly , installation, operation, repair and maintenance. they must be provided with the corresponding documentation.  danger of electric shock. emc filters contain components that store an electric charge. dangerous voltages can continue to exist at the filter terminals for longer than five min - utes even after the power has been switched of f.  the protective earth connections shall be the first to be made when the emc filter is installed and the last to be disconnected. depending on the magnitude of the leakage cur - rents, the particular specifications for making the protectiveearth connection must be ob - served.  impermissible overloading of the emc filter , such as with circuits able to cause reso - nances, impermissible voltages at higher frequencies etc. can lead to bodily injury and death as well as cause substantial material damages (e.g. destruction of the filter hous - ing).  emc filters must be protected in the application against impermissible exceeding of the rated currents by overcurrent protective.  in case of leakage currents > 3.5 ma you shall mount the pe conductor stationary with the required cross section before beginning of operation and save it against disconnect - ing. for leakage currents i l 4 ) < 10 ma the pe conductor must have a ku value 3 ) of 4.5; for leakage currents i l  10 ma the pe conductor must have a ku value of 6. 3) the ku value (symbol ku) is a classification parameter of safetyreferred failure types designed to ensure protection against hazardous body currents and excessive heating. a value of ku = 4.5 with respect to interruptions is attained: with a permanently connected protective earth circuit  1.5 mm 2 with a protective earth circuit  2.5 mm 2 connected via shroud connectors (iec 603092). ku = 6 with respect to interruptions is achieved for fixedconnection lines  10 mm 2 where the type of connection and line layout corre - spond to the requirements for pen conductors as specified in relevant standards. 4) i l = leakage current letgo please read important notes and cautions and warnings at the end of this document.    



3line filters b84143d0xxxr127 for converters and power electronics important notes the following applies to all products named in this publication: 1. some parts of this publication contain statements about the suitability of our products for cer - tain areas of application . these statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. w e nevertheless ex - pressly point out that such statement cannot be regarded as binding statements about the suit - ability of our products for a particular customer application . as a rule, epcos is either unfamil - iar with individual customer applications or less familiar with them than the customers themselves. for these reasons, it is always ultimately incumbent on the customer to check and decide whether an epcos product with the properties described in the product specification is suitable for use in a particular customer application. 2. w e also point out that in individual cases, a malfunction of passive electronic components or failure before end of their usual service life time cannot be completely ruled out in the current state of the art, even if they are operated as specified . in customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of a passive electronic component could endanger human life or health (e.g. in accident pre - vention or lifesaving systems), it must therefore be ensured by means of suitable design of the cus - tomer application or other action taken by the customer (e.g. installation of protective circuitry or re - dundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of a passive electronic component. 3. the warnings, cautions and productspecific notes must be observed . 4. in order to satisfy certain technical requirements, some of the products described in this publica - tion may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as ahazardouso) . useful information on this will be found in our material data sheets on the internet (www .epcos.com/material). should you have any more detailed questions, please contact our sales of fices. 5. w e constantly strive to improve our products. consequently , the products described in this publi - cation may change from time to time . the same is true of the corresponding product specifica - tions. please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order . w e also reserve the right to discontinue production and delivery of products . consequently , we cannot guarantee that all products named in this publication will always be available. 6. unless otherwise agreed in individual contracts, all orders subject to the current version of the ageneral t erms of delivery for products and services in the electrical industryo published by the the german electrical and electronics industry association (zvei) . 7. the trade names epcos, baoke, alux, ceradiode, cssp , mlsc, motorcap, phasecap, phasemod, siferrit , sifi, sikorel, silvercap, simid, siov , sip5d, sip5k, windcap are trademarks registered or pending in europe and in other countries. further information will be found on the internet at www.epcos.com/trademarks. 1 please read important notes and cautions and warnings at the end of this document.  
 





▲Up To Search▲   

 
Price & Availability of B84143D0075R127

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X